Walk-ins & refrigeration · 3 guides

Walk-in and commercial refrigeration guides

A warm walk-in or reach-in puts the food at risk before it puts the equipment at risk. These guides start with the food, then work through the checks in the order a technician makes them.

Guides

Start from what you can see

What you seeGo to
Cooler running warm, fans running or notWalk-in cooler not cooling
Coil solid with ice, in a cooler or a freezerWalk-in cooler not cooling — the ice section applies to both
Ice on the ceiling, fan guards or fan bladesWalk-in freezer problems
Freezer door frozen to the frame, or hard to pull openWalk-in freezer problems
Water or ice on the floor, ice in the drain panWalk-in freezer problems
A reach-in freezer or refrigerator (True, and similar) not getting coldTrue freezer not freezing

The numbers that matter

  • 41°F — the maximum for refrigerated food. Above that, a clock starts; after 5 hours or more, emergency guidance says the food must be destroyed.
  • 0°F — USDA's target for frozen storage. Food that still has ice crystals, or is no warmer than 40°F, can be refrozen.
  • Your health department has the final word on what can be sold.

A walk-in is two machines

The fan box inside, near the ceiling, is the evaporator. The compressor and condenser outside, on the roof or on top of the box, are the condensing unit. Whether each half is running is the first thing a technician wants to know, and the first thing the guides help you check. Doors, airflow, ice on the coil and a dirty condenser cause a large share of warm walk-ins, and all of them can be checked without tools. Refrigerant work needs an EPA Section 608 certified technician.